vSAN Alert
Definitions
VMware Aria
Operations
generates an alert if a problem occurs with the components in the
storage area network that the vSAN adapter is monitoring. Alerts for the vSAN
Cluster Object
Alerts on the vSAN Cluster
object have health, risk, and efficiency impact.
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
Basic (unicast) connectivity check (normal
ping) has failed on vSAN host.
| Storage
| Configuration
| Triggered when basic
(unicast) connectivity check (normal ping) has failed on the vSAN host due to
network misconfiguration.
|
Check the free space on physical disks in the
vSAN cluster.
| Storage
| Availability
| Triggered when a check
of free space on physical disks in the vSAN cluster results in an error or
warning.
|
CLOMD process on the host has issues and
impacting the functionality of vSAN cluster.
| Storage
| Availability
| Triggered when CLOMD
process on the host has issues and impacting the functionality of vSAN cluster.
|
Disk load variance between some vSAN disks
exceeded the threshold value.
| Storage
| Performance
| Triggered when disk
load variance between some vSAN disks exceeded the threshold value.
vSAN cannot perform
the load balance properly.
|
Host ESXi version and the vSAN disk format
version is incompatible with the other hosts and disks in a vSAN cluster.
| Storage
| Configuration
| Host ESXi version and
the vSAN disk format version is incompatible with the other hosts and disks in
a vSAN cluster.
|
Host has invalid unicast agent and impacting
the health of vSAN Stretched Cluster.
| Storage
| Configuration
| Triggered when the
host has invalid unicast agent and impacting the health of vSAN Stretched
Cluster.
An invalid unicast
agent on the host can cause a communication malfunction with the witness host.
|
Host in a vSAN cluster does not have a
VMkernel NIC configured for vSAN traffic.
| Network
| Configuration
| Triggered when the
host in a vSAN cluster does not have a VMkernel NIC configured for vSAN
traffic.
|
Host in a vSAN cluster has connectivity
issues and vCenter Server does not know its state.
| Network
| Configuration
| Triggered when the
host in a vSAN cluster has connectivity issues and vCenter Server does not know
its state.
|
Host in a vSAN cluster has IP multicast
connectivity issue.
| Network
| Configuration
| Triggered when the
host in a vSAN cluster has IP multicast connectivity issue. It means that
multicast is most likely the root cause of a vSAN network partition.
|
Host is either running an outdated version of
the vSAN Health Service VIB or It is not installed on the host.
| Storage
| Configuration
| Triggered when the
host is either running an outdated version of the vSAN Health Service VIB or It
is not installed on the host.
|
Network latency check of vSAN hosts failed.
It requires < 1 ms RTT.
| Network
| Configuration
| Triggered if network
latency check of vSAN hosts is greater than or equal to 1 ms RTT.
|
One or more hosts in the vSAN cluster have
misconfigured multicast addresses.
| Network
| Configuration
| Triggered when one or
more hosts in the vSAN cluster have misconfigured multicast addresses.
|
One or more physical disks on vSAN host is
experiencing software state health issues.
| Storage
| Availability
| Triggered when one or
more physical disks on vSAN host is experiencing software state health issues.
|
One or more vSAN enabled hosts are not in the same IP subnet. | Network
| Configuration
| Triggered when one or
more vSAN enabled hosts are not in the same IP subnet.
|
Overall health of the physical disks in a vSAN Cluster is
impacted. | Storage
| Availability
| Triggered when overall
health of the physical disks in a vSAN Cluster is impacted. See the health
status of each physical disk individually on all the hosts.
|
Overall health of VMs residing on vSAN datastore is reporting
issues. | Storage
| Availability
| Triggered when overall
health of the VMs on a vSAN datastore is impacted.
|
Overall health of vSAN objects is reporting issues. | Storage
| Availability
| Triggered when overall
health of vSAN objects is reporting issues.
|
Ping test with large packet size between all VMKernel adapters with
vMotion traffic enabled has issues. | Network
| Configuration
| Triggered when ping
test with large packet size between all VMKernel adapter with vMotion traffic
enabled is impacted.
|
Ping test with small packet size between all VMkernel adapters with
vMotion traffic enabled has issues. | Network
| Configuration
| Triggered when ping
test with small packet size between all VMKernel adapter with vMotion traffic
enabled is impacted.
|
Site latency between two fault domains and the witness host has exceeded
the recommended threshold values in a vSAN Stretched
cluster. | Storage
| Performance
| Site latency between
two fault domains and the witness host has exceeded the recommended threshold
values in a vSAN Stretched cluster.
|
Statistics collection of vSAN performance service is not working
correctly. | Storage
| Availability
| Triggered when
statistics collection of vSAN performance service is not working correctly.
This means that
statistics collection or writing statistics data to storage have failed for
three consecutive intervals.
|
MTU check (ping with large packet size) has failed on vSAN host. | Storage
| Configuration
| Triggered when MTU
check (ping with large packet size) has failed on vSAN environment due to some
MTU misconfiguration in the vSAN network.
|
The preferred fault domain is not set for the witness host in a vSAN
Stretched cluster. | Storage
| Configuration
| Triggered when the
preferred fault domain is not set for the witness host in a vSAN Stretched
cluster and affecting the operations of vSAN Stretched cluster.
|
Unicast agent is not configured on the host and affecting operations of
vSAN Stretched cluster. | Storage
| Configuration
| Triggered when unicast
agent is not configured on the host and affecting operations of vSAN Stretched
cluster.
|
vCenter Server has lost connection to a host that is part of a vSAN
cluster. | Storage
| Availability
| Triggered when the
host that is part of a vSAN cluster is in disconnected state or not responding
and vCenter Server does not know its state.
|
vSAN Cluster contains host whose ESXi version
does not support vSAN Stretched Cluster.
| Storage
| Configuration
| Triggered when vSAN
Cluster contains host whose ESXi version does not support vSAN Stretched
Cluster.
|
vSAN cluster has issues in electing stats master of vSAN Performance
service. This affects the functionality of vSAN Performance
service. | Storage
| Configuration
| Triggered when vSAN cluster has issues in electing
stats controller of vSAN Performance service. |
vSAN cluster has multiple network partitions. | Network
| Configuration
| Triggered when vSAN
cluster has multiple network partitions due to a network issue.
|
vSAN Cluster has multiple Stats DB objects which are creating conflicts
and affecting vSAN Performance Service. | Storage
| Configuration
| Triggered when vSAN cluster has issues in electing
stats controller of vSAN Performance service. This affects the
functionality of vSAN Performance service.
|
vSAN disk group has incorrect deduplication and compression
configuration. | Storage
| Configuration
| Triggered when vSAN
disk group has incorrect deduplication and compression configuration.
|
vSAN has encountered an issue while reading the metadata of a physical
disk. | Storage
| Availability
| Triggered when vSAN
has encountered an issue while reading the metadata of a physical disk and
cannot use this disk.
|
vSAN health service is not installed on the host. | Storage
| Configuration
| Triggered when vSAN
health service is not installed on the host.
|
vSAN host and its disks have inconsistent deduplication and compression
configuration with the cluster. | Storage
| Configuration
| Triggered when vSAN
host and its disks have inconsistent deduplication and compression
configuration with the cluster.
|
vSAN is unable to retrieve the physical disk information from
host. | Storage
| Availability
| Triggered when vSAN is
unable to retrieve the physical disk information from host. vSAN Health Service
may not be working properly on this host.
|
vSAN Performance Service is not enabled. | Storage
| Configuration
| Triggered when vSAN
Performance Service is not enabled.
|
vSAN Performance Service is unable to communicate and retrieve statistics
from host. | Storage
| Configuration
| Triggered when vSAN
Performance Service is unable to communicate and retrieve statistics from host.
|
vSAN Performance Service network diagnostic mode
is enabled for more than 24 hours. | Storage | Configuration | Triggered when the network diagnostic mode in vSAN
Performance Service is enabled for more than 24 hours. |
vSAN Stretched cluster contains a witness host without a valid disk
group. | Storage
| Configuration
| Triggered when vSAN
Stretched cluster contains a witness host without a valid disk group.
If the witness host
does not have any disk claimed by vSAN then its fault domain is not available.
|
vSAN Stretched cluster does not contain a valid witness host. | Storage
| Configuration
| Triggered when vSAN
Stretched cluster does not contain a valid witness host.
This affects the
operations of vSAN Stretched cluster.
|
vSAN Stretched cluster does not contain two valid fault domains. | Storage
| Configuration
| Triggered when vSAN
Stretched cluster does not contain two valid fault domains.
|
vSAN Stretched cluster has inconsistent configuration for Unicast
agent. | Storage
| Configuration
| Triggered when vSAN
Stretched cluster contains multiple unicast agents.
This means multiple
unicast agents were set on non-witness hosts.
|
vSAN witness host has an invalid preferred
fault domain.
| Storage
| Configuration
| Triggered when vSAN
witness host has an invalid preferred fault domain.
|
Witness host is a part of vSAN Stretched
cluster.
| Storage
| Configuration
| Triggered when witness
host is a part of the vCenter cluster, which forms vSAN Stretched cluster.
|
Witness host resides in one of the data fault
domains.
| Storage
| Configuration
| Triggered when witness
host resides in one of the data fault domains.
This affects the
operations of vSAN Stretched cluster.
|
Witness appliance upgrade to vSphere 7.0 or higher
with caution. | Storage | Configuration | Triggered when you want to upgrade the witness
applicance to vSphere 7.0 or higher. |
vSAN Support Insight is not enabled for the environment. | Storage | Configuration | Triggered when vSAN Support Insight is not enabled for the
environment. |
LSI 3108 controller’s advanced configuration values is different from
recommended values. | Storage | Configuration | Triggered when the LSI-3108 based controller configuration values
differs from vSAN configuration recommended values. |
vSAN Cluster flash read cache reservation is
approaching capacity. | Application | Performance | Triggered when the
flash read cache reservation in a vSAN cluster is less than
20%. Cleared by adding
more flash storage to the read-cache. |
Some vSAN hosts are not compliant with the
hyperconverged cluster configuration. | Storage | Configuration | Triggered when one of the host in vSAN cluster is
not compliant with the hyperconverged cluster configuration. |
Some vSAN hosts are not compliant for VMware
vSphere Distributed Switch configuration. | Storage | Configuration | Triggered when one of the host in vSAN cluster is
not compliant with the VMware vSphere Distributed Switch
configuration. |
Dual encryption is applied on virtual machines of
a vSAN cluster. | Storage | Availability | Triggered when dual encryption is applied on a
virtual machines of a vSAN cluster. |
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
After one additional host failure, vSAN
Cluster will not have enough resources to rebuild all objects
| Storage
| Capacity
| Triggered when after
one additional host failure, vSAN Cluster will not have enough resources to
rebuild all objects.
|
Capacity disk used for vSAN is smaller than
255 GB (default max component size).
| Storage
| Performance
| Triggered when a
capacity disk used for vSAN is smaller than 255 GB (default max component
size), so virtual machines that run on the vSAN Datastore might experience disk
space issues.
|
Capacity disk used for vSAN is smaller than
255 GB (default max component size).
| Storage
| Availability
| Triggered when a
capacity disk used for vSAN is smaller than 255 GB (default max component
size), so virtual machines that run on the vSAN Datastore might experience disk
space issues.
|
Controller with pass-through and RAID disks
has issues.
| Storage
| Configuration
| Triggered when a
controller with pass-through and RAID disks has issues.
|
Disk format version of one or more vSAN disks
is out of date
| Storage
| Configuration
| Triggered when the
disk format version of one or more vSAN disks is out of date and is not
compatible with other vSAN disks. This can lead to problems in creating or
powering on VMs, performance degradation, and EMM failures.
|
ESXi host issues retrieving hardware info.
| Storage
| Configuration
| Triggered when the
ESXi host issues retrieving hardware info.
|
Firmware provider hasn't all its dependencies
met or is not functioning as expected.
| Storage
| Configuration
| Triggered when a
firmware provider has not met all its dependencies or is not functioning as
expected.
|
Host with inconsistent extended
configurations is detected.
| Storage
| Configuration
| Triggered when a host
with inconsistent extended configurations is detected.
vSAN cluster extended
configurations are set as object repair timer is 60 minutes, site read locality
is Enabled, customized swap object is Enabled, large scale cluster support is
Disabled; For host with inconsistent extended configurations, vSAN cluster
remediation is recommended, for host doesn't support any extended
configuration, ESXi software upgrade is needed; And to make cluster scalability
configuration take effect, host reboot could be required.
|
Inconsistent configuration (like
dedup/compression, encryption) setup on hosts or disks with the cluster.
| Storage
| Configuration
| Triggered when there
is inconsistent configuration (like dedup/compression, encryption) setup on
hosts or disks with the cluster.
|
Network adapter driver is not VMware
certified.
| Storage
| Configuration
| Triggered when the
network adapter driver is not VMware certified.
|
Network adapter firmware is not VMware
certified.
| Storage
| Configuration
| Triggered when the
network adapter firmware is not VMware certified.
|
Network adapter is not VMware certified.
| Storage
| Configuration
| Triggered when the
network adapter is not VMware certified.
|
Network configuration of the vSAN iSCSI
target service is not valid.
| Storage
| Availability
| Triggered when the
network configuration of the vSAN iSCSI target service is not valid.
This health check
validates the presence of the default vmknic for the vSAN iSCSI target service,
and verifies that all the existing targets have valid vmknic configurations.
|
Non-vSAN disks are used for VMFS or Raw
Device Mappings(RDMs).
| Storage
| Availability
| Triggered when
non-vSAN disks are used for VMFS or Raw Device Mappings (RDMs).
|
Number of vSAN components on a disk is
reaching or has reached its limit.
| Storage
| Capacity
| Triggered when the
number of vSAN components on a disk is reaching or has reached its limit. This
will cause failure in the deployment of new Virtual Machines and also impact
rebuild operations.
|
Number of vSAN components on a host is
reaching or has reached its limit.
| Storage
| Capacity
| Triggered when the
number of vSAN components on a host is reaching or has reached its limit.
This will cause
failure in the deployment of new Virtual Machines and also impact rebuild
operations.
|
One or more ESXi hosts in the cluster do not
support CPU AES-NI or have it disabled.
| Storage
| Availability
| Triggered when one or
more hosts in the cluster do not support CPU AES-NI or have it disabled. As a
result, the system might use the software encryption that is significantly
slower than AES-NI.
|
RAID controller configuration has issues.
| Storage
| Configuration
| Triggered when the
RAID controller configuration has issues.
|
Storage I/O controller driver is not VMware
certified
| Storage
| Configuration
| Triggered when the
stability and integrity of vSAN may be at risk as the storage I/O controller
driver is not VMware certified.
|
Storage I/O controller drivers is not
supported with the current version of ESXi running on the host
| Storage
| Configuration
| Triggered when the
stability and integrity of vSAN may be at risk as the storage I/O controller
driver is not supported with the current version of ESXi running on the host.
|
Storage I/O Controller firmware not is VMware
certified.
| Storage
| Configuration
| Triggered when the
storage I/O Controller firmware not is VMware certified.
|
Storage I/O controller is not compatible with
the VMware Compatibility Guide
| Storage
| Configuration
| Triggered when the
vSAN environment may be at risk as the Storage I/O controller on the ESXi hosts
that are participating in a vSAN cluster are not compatible with the VMware
Compatibility Guide.
|
The current status of the Customer Experience
Improvement Program (CEIP) not is enabled.
| Storage
| Availability
| Triggered when the
current status of the Customer Experience Improvement Program (CEIP) not is
enabled.
|
The Internet connectivity is not available
for vCenter Server.
| Storage
| Availability
| Triggered when
internet connectivity is not available for vCenter Server.
|
The resync operations are throttled on any
hosts.
| Storage
| Configuration
| Triggered when resync
operations are throttled. Please clear the limit, unless you need it for
particular cases like a potential cluster meltdown.
|
Time of hosts and VC are not synchronized
within 1 minute.
| Storage
| Configuration
| Triggered when the
time of hosts and VC are not synchronized within 1 minute.
Any difference larger
than 60 seconds will lead this check to fail. If the check fails, it is
recommended that you check the NTP server configuration.
|
vCenter Server or any of the ESXi hosts
experience problems when connecting to Key Management Servers (KMS).
| Storage
| Availability
| Triggered when the
vCenter Server or any of the hosts experience problems when connecting to KMS.
|
vCenter server state was not pushed to ESXi
due to vCenter server being out of sync.
| Storage
| Configuration
| Triggered when the
vCenter server state was not pushed to ESXi due to vCenter server being out of
sync.
During normal
operation, the vCenter server state is regarded as source of truth, and ESXi
hosts are automatically updated with the latest host membership list. When
vCenter server is replaced or recovered from backup, the host membership list
in vCenter server may be out of sync. This health check detects such cases, and
alerts if vCenter server state was not pushed to ESXi due to vCenter server
being out of sync. In such cases, first fully restore the membership list in
vCenter server, and then perform 'Update ESXi configuration' action if
required.
|
vSAN and VMFS datastores are on a same Dell
H730 controller with the lsi_mr3driver.
| Storage
| Configuration
| Triggered when the
vSAN and VMFS datastores are on a same Dell H730 controller with the
lsi_mr3driver.
|
vSAN build recommendation based on the
available releases and VCG compatibility guide.
| Storage
| Availability
| Triggered when the
vSAN build is not compatible with available releases and VCG compatibility
guide.
This is the ESXi build
that vSAN recommends as the most appropriate, given the hardware, its
compatibility per the VMware Compatibility Guide and the available releases
from VMware.
|
vSAN build recommendation engine has all its
dependencies met and is functioning as expected.
| Storage
| Availability
| Triggered when the
vSAN build recommendation engine has issues.
The vSAN Build
Recommendation Engine relies on the VMware compatibility guide and VMware
release metadata for its recommendation. To provide build recommendations, it
also requires VMware Update Manager service availability, internet
connectivity, and valid credentials for my.vmware.com. This health check
ensures that all dependencies are met and that the recommendation engine is
functioning correctly.
|
Some disk(s) free space in vSAN Cluster is less than 10% | Storage
| Capacity
| Triggered when the disk usage in a vSAN cluster
reaches 90% of capacity. Cleared by removing
virtual machines that are no longer in use or adding more disks to the cluster.
|
Some disk(s) free space in vSAN Cluster is less than 30% | Storage
| Capacity
| Triggered when the disk usage in a vSAN cluster
reaches 70% of capacity. Cleared by removing
virtual machines that are no longer in use or adding more disks to the cluster.
|
vSAN cluster is reaching or has reached its
limit for components, free disk space and read cache reservations.
| Storage
| Capacity
| Triggered when the
vSAN cluster is reaching or has reached its limit for components, free disk
space and read cache reservations.
|
vSAN Cluster virtual disk count capacity is
less than 5%.
| Storage
| Capacity
| Triggered when the
number of virtual disks per host in the vSAN cluster reaches 95% of capacity.
Cleared by adding
most hosts to the cluster.
|
vSAN Cluster virtual disk count is
approaching capacity.
| Storage
| Capacity
| Triggered when the
number of virtual disks per host in the vSAN cluster reaches 75% of capacity.
Cleared by adding
most hosts to the cluster.
|
vSAN configuration for LSI 3108-based
controller has issues.
| Storage
| Configuration
| Triggered when the
vSAN configuration for LSI 3108-based controller has issues.
|
vSAN disk group type (All-Flash or Hybrid)
for the used SCSI controller is not VMware certified.
| Storage
| Configuration
| Triggered when the
vSAN disk group type (All-Flash or Hybrid) for the used SCSI controller is not
VMware certified.
|
vSAN enabled hosts have inconsistent values
for advanced configuration options.
| Storage
| Configuration
| Triggered when some
advanced configuration settings have different values on different hosts in the
vSAN cluster.
|
vSAN firmware version recommendation based on
the VCG.
| Storage
| Configuration
| Triggered when the vSAN firmware version
recommendation based on the VCG check has issues.
|
vSAN has encountered an integrity issue with
the metadata of an individual component on a physical disk.
| Storage
| Availability
| Triggered when the
vSAN has encountered an integrity issue with the metadata of an individual
component on a physical disk.
|
vSAN HCL DB auto updater is not working
properly.
| Storage
| Configuration
| Triggered when the
vSAN HCL DB auto updater is not working properly. This means that vSAN cannot
download and update its HCL DB automatically.
|
vSAN HCL DB is not up-to-date.
| Storage
| Configuration
| Triggered when the
vSAN HCL DB is not up-to-date.
|
vSAN Health Service is not able to find the
appropriate controller utility for the storage controller on the ESXi host.
| Storage
| Availability
| Triggered when the
vSAN Health Service is not able to find the appropriate controller utility for
the storage controller on the ESXi host.
|
vSAN is running low on the vital memory pool
(heaps) needed for the operation of physical disks.
| Storage
| Performance
| Triggered when the
vSAN is running low on the vital memory pool (heaps) needed for the operation
of physical disks.
This can lead to a
variety of performance issues such as virtual machine storage performance
degradation, operation failures, or even ESXi hosts going unresponsive.
|
vSAN is running low on the vital memory pool
(slabs) needed for the operation of physical disks.
| Storage
| Performance
| Triggered when the
vSAN is running low on the vital memory pool (slabs) needed for the operation
of physical disks.
This can lead to a
variety of performance issues such as virtual machine storage performance
degradation, operation failures, or even ESXi hosts going unresponsive.
|
vSAN is using a physical disk which has high
congestion value.
| Storage
| Performance
| Triggered when the
vSAN is using a physical disk which has high congestion value.
This can lead to a
variety of performance issues such as virtual machine storage performance
degradation, operation failures, or even ESXi hosts going unresponsive.
|
vSAN iSCSI target service home object has
issues.
| Storage
| Availability
| Triggered when the
vSAN iSCSI target service home object has issues.
This health check
verifies the integrity of the vSAN iSCSI target service home object. It also
verifies that the configuration of the home object is valid.
|
vSAN iSCSI target service is not running
properly or is not correctly enabled on the host.
| Storage
| Availability
| Triggered when the
vSAN iSCSI target service is not running properly or is not correctly enabled
on the host.
This health check
verifies the service runtime status of the vSAN iSCSI target service, and
checks whether the service is correctly enabled on each host.
|
vSAN performance service statistics database
object is reporting issues.
| Storage
| Availability
| Triggered when the
vSAN performance service statistics database object is reporting issues.
|
vSphere cluster members do not match vSAN
cluster members.
| Storage
| Configuration
| Triggered when the
vSphere cluster members do not match vSAN cluster members.
|
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
vSAN Cluster flash read cache is approaching
capacity.
| Storage
| Capacity
| Triggered when the
Read Cache (RC) in the vSAN cluster reaches 80% of capacity.
Cleared by adding
flash storage to the read cache.
|
vSAN Cluster flash read cache capacity is
less than 5%.
| Storage
| Capacity
| Triggered when the
Read Cache (RC) in the vSAN cluster reaches 95% of capacity.
Cleared by adding
flash storage to the read cache.
|
vSAN Adapter Instance
Object Alert Definitions
Alerts on the vSAN Adapter
Instance Object have health impact.
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
vSAN adapter instance failed to collect
data from vSAN Health Service. The health Service might have issues.
| Storage
| Configuration
| Triggered when the
vSAN adapter instance failed to collect data from vSAN Health Service. The
health Service might have issues.
|
vSAN Disk Group Object
Alert Definitions
Alerts on the vSAN Disk Group
Object have efficiency impact.
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
vSAN Disk Group read cache hit rate is less
than 90%.
| Storage
| Performance
| Triggered when the
vSAN disk group read cache hit rate is less than 90%.
Cleared by adding
more cache to accommodate the workload.
|
vSAN Disk Group read cache hit rate is less
than 90% and write buffer free space is less than 10%.
| Storage
| Capacity
| Triggered when the
vSAN disk group read cache hit rate is less than 90% and the vSAN disk group
write buffer free space is less than 10%.
Cleared by adding
more flash capacity to the vSAN disk group.
|
vSAN Host Object Alert
Definitions
Alerts on the vSAN Host Object
have security impact.
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
vSAN host has encryption disabled, while
the vSAN cluster has encryption enabled.
| Storage
| Configuration
| Triggered when the
vSAN host has encryption disabled, while the vSAN cluster has encryption
enabled.
Cleared by enabling
encryption on vSAN host.
|
vSAN host encryption is enabled, while the
vSAN cluster encryption is disabled.
| Storage
| Configuration
| Triggered when the
vSAN host has encryption enabled, while the vSAN cluster has encryption
disabled.
Cleared by enabling
encryption on vSAN cluster.
|
vSAN Capacity Disk
Object Alert Definitions
Alerts on the vSAN Capacity
Disk object have security impact.
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
vSAN capacity disk has encryption disabled,
while the vSAN cluster has encryption enabled.
| Storage
| Configuration
| Triggered when the
vSAN capacity disk has encryption disabled, while the vSAN cluster has
encryption enabled.
Cleared by enabling
encryption on vSAN capacity disk.
|
vSAN capacity disk encryption is enabled, while
the vSAN cluster encryption is disabled. | Storage | Configuration | Triggered when the
vSAN capacity disk has encryption enabled, while the vSAN
cluster has encryption disabled. Cleared by enabling
encryption on vSAN cluster. |
The free read cache reservations across the entire
vSAN cluster are beyond the thresholds. | Storage | Capacity | Triggered when the flash read cache is
exhausted. Flash read cache is only relevant to hybrid configurations and
is not relevant on all-flash configurations. |
Deployment of new virtual machines fails due to insufficient disk
capacity | Storage
| Capacity | Triggered when the disk capacity of the vSAN cluster exceeds the
threshold value. |
vSAN Cache Disk Object
Alert Definitions
Alerts on the vSAN Cache Disk
object have security impact.
Alert
| Alert Type
| Alert Subtype
| Description
|
---|---|---|---|
vSAN cache disk has encryption disabled,
while the vSAN cluster has encryption enabled.
| Storage
| Configuration
| Triggered when the
vSAN cache disk has encryption disabled, while the vSAN cluster has encryption
enabled.
Cleared by enabling
encryption on vSAN cache disk.
|
vSAN cache disk encryption is enabled,
while the vSAN cluster encryption is disabled.
| Storage
| Configuration
| Triggered when the
vSAN cache disk has encryption enabled, while the vSAN cluster has encryption
disabled.
Cleared by enabling
encryption on vSAN cluster.
|
vSAN File Service Alert
Definitions
Alert | Alert Type | Alert Subtype | Description |
---|---|---|---|
vSAN File Service infrastructure health has
issues. | Storage | Configuration | Triggered when there
is an issue with file service infrastructure health state of an
ESXi host in the vSAN cluster. |
vSAN File Share health is not in a good
state. | Storage | Configuration | Triggered when the vSAN File Share health is not
in a good state. |
Network File System (NFS) daemon is not running. | Storage | Configuration | Triggered when the NFS daemon process is not
running. |
Root File System is inaccesible. | Storage | Configuration | Triggered when the root file system does not
repond to the file server. |
File Server IP address not assigned. | Storage | Configuration | Triggered when IP address is not assigned to the
file server. |
vSAN File Server health is not in a good state. | Storage | Configuration | Triggered when the
vSAN File Server health is not in a good state. |