Create a Network Pool

A network pool must include the vMotion network information. Depending on the type of storage you are using, you must provide network information for vSAN, NFS, and iSCSI.
The subnet in a network pool cannot overlap the subnet of another pool.
  1. In the navigation pane, click
    Administration
    Network Settings
    .
  2. Click
    Create Network Pool
    .
  3. Enter a name for the network pool.
  4. Select the network type(s).
    • For vSAN and NFS, you can include both vSAN and NFS network information in the same network pool or create separate network pools for vSAN and NFS.
    • For VMFS on FC storage, select vMotion only or vMotion and NFS.
    • For vVols on FC storage, select vMotion only or vMotion and NFS.
    • For vVols on iSCSI storage, select vMotion and iSCSI.
    • For vVols on NFS storage, select vMotion and NFS.
  5. Provide the following network information for the selected network type(s).
    Option
    Description
    VLAN ID
    Enter a VLAN ID between 1 and 4094.
    MTU
    Enter an MTU between 1500 and 9000.
    Network
    Enter a subnet IP address.
    Subnet Mask
    Enter the subnet mask.
    Default Gateway
    Enter the default gateway.
    Included IP Ranges
    Enter an IP address range from which an IP address can be assigned to hosts that are associated with this network pool. The IP address range must be from within the specified subnet. You cannot include the IP address of the default gateway in the IP address range. You can enter multiple IP address ranges.
    Ensure that you have entered the correct IP address range. IP ranges cannot be edited after the network pool is created.
  6. Click
    Save
    .