Component Log Files Collected by the SoS
UtilityLast Updated January 30, 2025
The SoS utility writes the component log files into an
output directory structure within the file system of the
SDDC
Manager
instance in which the command is initiated, for example: esx Directory
Contents
esx
Directory
ContentsIn each rack-specific directory, the
esx
directory contains the following diagnostic files
collected for each ESXi host in the rack: File | Description |
---|---|
esx- FQDN .tgz | Diagnostic information
from running the
vm-support command on
the ESXi host.
An example file is esx-esxi-1.vrack.vsphere.local.tgz . |
SmartInfo- FQDN .txt | S.M.A.R.T. status of the
ESXi host's hard drive (Self-Monitoring, Analysis, and Reporting Technology).
An example file is SmartInfo-esxi-1.vrack.vsphere.local.txt . |
vsan-health- FQDN .txt | VMware
vSAN cluster
health information from running the standard command
python
/usr/lib/vmware/vsan/bin/vsan-health-status.pyc on the ESXi host.
An example file is vsan-health-esxi-1.vrack.vsphere.local.txt . |
nsx Directory
Contents
nsx
Directory
ContentsIn each rack-specific directory, the
nsx
directory contains the diagnostic information files
collected for the NSX
Managers
and NSX Edge instances deployed in that rack. The number of files in this directory depends on the
number of
NSX
Manager
and NSX Edge instances that are deployed in the rack. In a
given rack, each management domain has a cluster of three NSX Managers
.
The first VI workload domain has an additional cluster of three NSX Managers
.
Subsequent VI workload domains can deploy their own NSX Manager cluster, or use the
same cluster as an existing VI workload domain. NSX Edge instances are optional. File | Description |
---|---|
VMware-NSX-Manager-tech-support- nsxmanagerIPaddr .tar.gz | Standard NSX
Manager compressed support bundle, generated using the
NSX API POST https:// ,
where nsxmanagerIPaddr /api/1.0/appliance-management/techsupportlogs/NSXnsxmanagerIPaddr is the IP address of the NSX
Manager instance. An example is
VMware-NSX-Manager-tech-support-10.0.0.8.tar.gz. |
VMware-NSX-Edge-tech-support- nsxmanagerIPaddr -edgeId .tgz This information is only
collected if NSX Edges are deployed. | Standard NSX Edge support bundle, generated using the NSX API
to query the NSX Edge support logs: GET https:// , where nsxmanagerIPaddr /api/4.0/edges/edgeId /techsupportlogsnsxmanagerIPaddr
is the IP address of the NSX
Manager instance and edgeID
identifies the NSX Edge instance. An example is VMware-NSX-Edge-tech-support-10.0.0.7-edge-1.log.gz.
|
vc Directory
Contents
vc
Directory
ContentsIn each rack-specific directory, the
vc
directory contains the diagnostic information files
collected for the vCenter Server
instances deployed in that rack. The number of files in this
directory depends on the number of
vCenter
Server
instances that are deployed in the rack. In a given rack,
each management domain has one
vCenter
Server
instance, and any VI workload domains in the rack each
have one
vCenter
Server
instance.
File | Description |
---|---|
vc- vcsaFQDN -vm-support.tgz | Standard vCenter
Server support bundle downloaded from the vCenter Server
Appliance instance having a fully qualified domain name
vcsaFQDN . The support bundle is obtained from the instance
using the standard vc-support.sh command. |