Monitor and Manage FibreChannel SAN Storage

The
esxcli storage san commands
help administrators troubleshoot issues with I/O devices and fabric, and include Fibre Channel, FCoE, iSCSI, SAS protocol statistics.
The commands allow you to retrieve device information and I/O statistics from those device. You can also issue Loop Initialization Primitives (LIP) to FC/FCoE devices and you can reset SAS devices.
For FC and FCoE devices, you can retrieve FC events such as
RSCN
,
LINKUP
,
LINKDOWN
, Frame Drop and
FCoE CVL
. The commands log a warning in the VMkernel log if it encounters too many Link Toggling or frame drops.
The following example examines and resets SAN storage through a FibreChannel adapter. Instead of fc, the information retrieval commands can also use
iscsi
,
fcoe
, and
sas
.
  1. List adapter attributes.
    esxcli storage san fc list
  2. Retrieve all events for a Fibre Channel I/O device.
    esxcli storage san fc events get
  3. Clear all I/O Device Management events for the specified adapter.
    esxcli storage san fc events clear --adapter adapter
  4. Reset the adapter.
    esxcli storage san fc reset