Linking and Unlinking
Uplink Adapters with vicfg-vswitch
You can use
vicfg-vswitch
to link
and unlink uplink adapters.
When you create a virtual switch
by using
vicfg-vswitch --add
, all traffic on that virtual switch
is initially confined to that virtual switch. All virtual machines connected to
the virtual switch can talk to each other, but the virtual machines cannot
connect to the network or to virtual machines on other hosts. A virtual machine
also cannot connect to virtual machines connected to a different virtual switch
on the same host.
Having a virtual switch that is
not connected to the network might make sense if you want a group of virtual
machines to be able to communicate with each other, but not with other hosts or
with virtual machines on other hosts. In most cases, you set up the virtual
switch to transfer data to external networks by attaching one or more uplink
adapters to the virtual switch.
You can use the following
commands to add and remove uplink adapters.
- Add a new uplink adapter to a virtual switch.vicfg-vswitch <conn_options> --link vmnic15 vSwitch0
- Remove an uplink adapter from a virtual switch.vicfg-vswitch <conn_options> --unlink vmnic15 vSwitch0