Rescanning Datastores Fails Because Storage Devices are Not Ready

When you start a test recovery or a recovery, some SRAs send responses to
Site Recovery Manager
before a promoted storage device on the recovery site is available to the
ESXi
hosts.
Site Recovery Manager
rescans the storage devices and the rescan fails.
If storage devices are not fully available yet,
ESXi
Server does not detect them and
Site Recovery Manager
does not find the replicated devices when it rescans. This can cause several problems.
  • Datastores are not created and recovered virtual machines cannot be found.
  • ESXi
    hosts become unresponsive to
    vCenter Server
    heartbeat and disconnect from
    vCenter Server
    . If this happens,
    vCenter Server
    sends an error to
    Site Recovery Manager
    and a test recovery or real recovery fails.
  • The
    ESXi
    host is available, but rescanning and disk resignaturing exceed the
    Site Recovery Manager
    or
    vCenter Server
    timeouts, resulting in a
    Site Recovery Manager
    error.
The storage devices are not ready when
Site Recovery Manager
starts the rescan.
To delay the start of storage rescans until the storage devices are available on the
ESXi
hosts, increase the
storageProvider.hostRescanDelaySec
setting to a value between 20 and 180 seconds. See Change Storage Provider Settings.